Humidity control which is adjustable between 40% RH and 95% RH Complete with integral adjustable timer (1-20 mins) with pullcord override switch. Requires no switched live.
Perfect for bathrooms and toilets, this super range of domestic 4″ fans offer an impressive extract rate of 85m3/hr and 23 litres per second and can be wall or ceiling mounted. Made using tough and durable ABS thermosplastics, the power is provided by a single phase induction motor with pre-oiled bearings
Installation
XF100 Series bathroom fans are designed for wall mounting (pullcord version wall mounting only) through 100mm (4″) diameter flexible or rigid pipes or Manrose low profile, flat channel ducting systems.
Electrical
220-240V – AC. 50Hz . Single phase consuming 15 Watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.
Additional Data
- 100mm (4″)
- Range Maximum pressure: 20 p.a.
- Fan speed: 2400 r.p.m.
- Sound volume: 41.0 dB(A)
- Maximum operating temperature: 40ºC
- Mains Voltage: 220-240V – AC. 50Hz
- Spigot Size: 98mm